HFH029U liner range

HFH029 banner

HFH029U LINER RANGE

Unvented versions

HFH029U, HFH029U-01 & HFH029U-B

 

Alternate & simultaneous milking

Recommendations for milking settings:

  • Phases:

    Phase A: 120-130 ms;

    Phase B: 460-480 ms;

    Phase C: 120-140 ms; 

    Phase D: 200-240 ms.

  • Ratio: 63:37 to 65:35
  • Rate: 62,5 bpm to 64 bpm
  • Peak flow claw vacuum: 36-38 kPa
  • Take-off limit: 

    Min. 500-600 ml for 2 milkings per day;

    Min. 800 ml for 3 milkings per day.

  • Take-off time: 3-5 sec. depending on cluster weight.

Vented Versions

HFH029U Air, HFH029U-01 Air & HFH029U-B Air

 

Alternate & simultaneous milking

Recommendations for milking settings:

  • Phases:

    Phase A: 120-130 ms;

    Phase B: 460-480 ms;

    Phase C: 120-140 ms; 

    Phase D: 200-240 ms.

  • Ratio: 63:37 to 65:35
  • Rate: 62,5 bpm to 64 bpm
  • Peak flow claw vacuum: 38-40 kPa
  • Take-off limit: 

    Min. 500-600 ml for 2 milkings per day;

    Min. 800 ml for 3 milkings per day.

  • Take-off time: 1 sec. depending on cluster weight.

Herd recommendations

Teat thickness: middle 22-23 mm

Teat shape:

parallel teats
Parallel teats

 

Conical teats
Conical teats

Teat positioning: 

teat positioning
Normal

 

teat positioning
Inside

 

teat positioning
Outside

Udder shape:

straight
Straight udder shape

 

stepped
Stepped udder shape

Udder height: normal or high

Milkability: easy or difficult

Milk line dedication: highline, swingover, or parlour

 